SHANGHAI TOPS GROUP CO., LTD

21 Years Manufacturing Experience

How will Ribbon Blenders’ Minor Problems Be Solved?

acdsv (1)

Unavoidable troubles can at times occur while using the ribbon blenders. The good news is that there are certain ways to fix these flaws.

acdsv (2)
acdsv (3)

Typical machine problems

- After pushing the start button, the ribbon blenders does not begin to operate.

acdsv (4)

Probable Reason

- There might be a problem with the electrical wiring, an improper voltage, or a disconnected power source.

- The ribbon blender’s power source is cut off when the circuit breaker trips or is switched off.

- As a safety precaution, the mixer cannot start if the lid is not securely closed, or the interlock key is not inserted.

- The mixer cannot operate since there is no time limit defined for the operation if the timer is set to 0 seconds.

acdsv (5)

The potential solution

- To make sure the power source is correctly connected and turned on, check the voltage.
- To see if the circuit breaker is on, open the electrical panel.

- Make sure the lid is closed properly or that the interlock key is placed in the right way.

- Make sure the timer is set to anything other than zero.

- If the 4 steps are followed exactly and the mixer still won't start, please make a video showing all four steps and get in touch with us for more help.

acdsv (6)

Typical machine problems

- When the mixer is operating, it abruptly stops.

savv
acdsv (4)

Probable Reason

- The ribbon blenders could not start or function correctly if the power supply voltage was off.

- The thermal protection may have been triggered by the motor overheating, which may have been brought on by an overload or other issues.

- The ribbon blenders may shut down if materials are overfilled, since going over the capacity limit may hinder appropriate functioning.

- When foreign things clog the shaft or bearings, the machine's regular operation may be impeded.

- The sequence in which the mixing's materials are added.

acdsv (5)

The potential solution

- After disconnecting the power source, look for any irregularities. Check with a multi-meter to see whether the machine voltage and the surrounding voltage match. Please get in touch with us to check the accurate voltage if there are any differences.

- Check to see if the heat protection has tripped and been engaged by opening the electrical panel.
- Disconnect the power source and see whether the material is overfilled if the device trips.When the amount of material in the mixing tank is 70% full, remove more of it.

- Examine the shaft and bearing positions for any foreign items that may be lodged there.

- Make sure there are no deviations in stages 3 or 4.


Post time: Dec-22-2023