Unavoidable troubles can at times occur while using the ribbon blenders. The good news is that there are certain ways to fix these flaws.
Typical machine problems
- After pushing the start button, the ribbon blenders does not begin to operate.
Probable Reason
- There might be a problem with the electrical wiring, an improper voltage, or a disconnected power source.
- The ribbon blender’s power source is cut off when the circuit breaker trips or is switched off.
- As a safety precaution, the mixer cannot start if the lid is not securely closed, or the interlock key is not inserted.
- The mixer cannot operate since there is no time limit defined for the operation if the timer is set to 0 seconds.
The potential solution
- To make sure the power source is correctly connected and turned on, check the voltage.
- To see if the circuit breaker is on, open the electrical panel.
- Make sure the lid is closed properly or that the interlock key is placed in the right way.
- Make sure the timer is set to anything other than zero.
- If the 4 steps are followed exactly and the mixer still won't start, please make a video showing all four steps and get in touch with us for more help.
Typical machine problems
- When the mixer is operating, it abruptly stops.
Probable Reason
- The ribbon blenders could not start or function correctly if the power supply voltage was off.
- The thermal protection may have been triggered by the motor overheating, which may have been brought on by an overload or other issues.
- The ribbon blenders may shut down if materials are overfilled, since going over the capacity limit may hinder appropriate functioning.
- When foreign things clog the shaft or bearings, the machine's regular operation may be impeded.
- The sequence in which the mixing's materials are added.
The potential solution
- After disconnecting the power source, look for any irregularities. Check with a multi-meter to see whether the machine voltage and the surrounding voltage match. Please get in touch with us to check the accurate voltage if there are any differences.
- Check to see if the heat protection has tripped and been engaged by opening the electrical panel.
- Disconnect the power source and see whether the material is overfilled if the device trips.When the amount of material in the mixing tank is 70% full, remove more of it.
- Examine the shaft and bearing positions for any foreign items that may be lodged there.
- Make sure there are no deviations in stages 3 or 4.
Post time: Dec-22-2023